Order quantity: In measures of 1.0 running meters. This product is cut off according to your specifications, a return is not possible. Please request a free sample before an order.
MOQ (minimum order quantity): 10 meters
Application: Reduction of LF fields
Field type: LF (low frequency)

Low priced shielded installation cables for the protection against low-frequency electric fields (LF). For installations over, up, in and under finery, in dry, moistens and wet areas, as well as in the brick-work and concrete. Also suitable for use outside, if protected against sun exposure. Excluded for direct imbedding in vibration, shaking and ramming concrete.

Technical data

  • Shielded PVC-sheathed cable (adapted to DIN VDE 0250 part 204/209)
  • PVC self-extinguishing and flame retardant according to VDE 0482-332-1-2, DIN EN 60332-1-2 / IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)
  • CE = This product is conform with the EC Low-Voltage Directive 2006/95/EG
  • Direct current resistance to DIN VDE 0295
  • Operating temperature -40°C to +70°C, cabling temperature -5°C to +70°C
  • Nominal voltage U0/U: 300/500 V, current load according to VDE 0100
  • Test procedures according to DIN VDE 0472, test ac voltage 50 Hz, 2000 V
  • Bending radius accoording to DIN VDE 0298: 4 x D
  • Radiation resistance: Up to 80x106 cJ/kg (up to 80 Mrad)

Variants

 Wire count / cross section
 Outer diameter
 Weight
 3 x 1.5 mm²  10.5 mm  154 g/m
 3 x 2.5 mm²  12.0 mm  217 g/m
 5 x 1.5 mm²  12.0 mm  208 g/m
 5 x 2.5 mm²  13.5 mm  208 g/m








Construction

1) Solid copper conductor; 2) Insulation: cross linked polyethylene; 3) Common PVC core covering;  4) (St)-Screen: Coated aluminium foil with 1.5 mm wire; 5) PVC outer sheath;

Information on installing

Connect the ground wiring of the junction box with the ground wiring of the cable during installation! Always connect green-yellow with green-yellow, in no case connect it with the continuity wire! Protect the bare continuity wire and the foil with insulating tube. There must not be any conductive components in the junction box! Connect the shield connector = continuity wire on one side to the earth circuit connector. Do not use shielded and unshielded cables at the same time.

ΠΡΟΣΟΧΗ: ΤΑ ΠΡΟΪΟΝΤΑ ΠΟΥ ΚΟΒΟΝΤΑΙ ΚΑΙ ΠΩΛΟΥΝΤΑΙ ΜΕ ΤΟ ΜΕΤΡΟ ΟΠΩΣ ΥΦΑΣΜΑ, ΠΛΕΓΜΑ, ΦΙΛΜ ΤΖΑΜΙΩΝ, ΚΑΛΩΔΙΑ ΔΕΝ ΕΠΙΣΤΡΕΦΟΝΤΑΙ

Θωρακισμένο καλώδιο 5 στρώσεων (N)YM(St)-J 3 x 1.5

  • 2,00€

  • Χωρίς ΦΠΑ:
    1,61€

  • 50 ή περισσότερα 1,81€

Διαθέσιμες Επιλογές


Το προϊόν έχει ελάχιστη ποσότητα 15 τεμ.

Ετικέτες: Θωρακισμένο καλώδιο 5 στρώσεων (N)YM(St)-J 3 x 1.5, NYM(St)-J-3x1.5, ΘΩΡΑΚΙΣΗ > ΗΛΕΚΤΡΙΚΑ - ELECTROSMOG, EMF EMR Anti Radiation Θωράκιση Ακτινοβολίας

Αν χρειάζεστε βοήθεια

Αν διαβάσατε την παραπάνω περιγραφή και χρειάζεστε βοήθεια για το προϊόν καλέστε μας στο: (210) 3212-500 ή στείλτε μας e-mail.

Βοήθεια είναι διαθέσιμη σε Ελληνικά και Αγγλικά.

Πιστοποιητικό

Δείτε τα πιστοποιητικά για τά Ελληνικά προϊόντα από το Τμήμα Βιολογίας του Πανεπιστημίου Αθηνών (ΕΚΠΑ) ΕΔΩ.